Make: Kidde Graviner
Type: Mark 6
Item: Oil Mist Detector
The Graviner Mark 6 retains the long-established differential measuring system, enabling high sensitivity while maintaining maximum false alarm rejection. It uses optical sensing based on light scatter instead of obscuration, allowing for the use of very small detectors. These detectors are rugged and designed to be engine-mounted using standard oil mist detector ports, with each having its means of sample acquisition, eliminating the need for sample pipes. Multiple internal light sources ensure that a single failure will not cause the loss of a detector. The modular construction allows for a faulty detector to be replaced in a matter of minutes.
Following are the Part Numbers of the System:
1.P/N :13455-D033 Door seal
2.P/N:27411-K001 Fuse, 4 Amp., 20 mm, slow blow
3.P/N: 35100-K187 Bezel
4.P/N:39155-K047 Function Key Membrane (Rev 2.0)
5.P/N: 39155-K048 Status display Membrane (Rev 2.0)
6.P/N:43682-K032 Cable Harness
7.P/N:43682-K037 Loom
8.P/N 43682-K108 Cable assy 2,5 m – straight connector
9.P/N 43682-K108-00 Cable assy 5,0 m – straight connector
10.P/N 43682-K108-01 Cable assy 7,5 m – straight connector
11.P/N 43682-K108-02 Cable assy 10,0 m – straight connector
12.P/N 43682-K108-03 Cable assy 12,5 m – straight connector
13.P/N 43682-K108-04 Cable assy 15,0 m – straight connector
14.P/N 43682-K108-05 Cable assy 17,5 m – straight connector
15.P/N 43682-K108-06 Cable assy 20,0 m – straight connector
16.p/N 43682-K108-07 Cable assy 22,5 m – straight connector
17.P/N 43682-K108-08 Cable assy 25,0 m – straight connector
18.P/N 43682-K109 Cable assy 2,5 m – 90° connector
19.P/N 43682-K109-00 Cable assy 5,0 m – 90 connector
20.P/N 43682-K109-01 Cable assy 7,5 m – 90 connector
21.P/N 43682-K109-02 Cable assy 10,0 m – 90° connector
22.P/N 43682-K109-03 Cable assy 12,5 m – 90 connector
23.P/N 43682-K109-04 Cable assy 15,0 m – 90° connector
24.P/N 43682-K109-05 Cable assy 17,5 m – 90° connector
25.P/N 43682-K109-06 Cable assy 20,0 m – 90° connector
26.P/N 43682-K109-07 Cable assy 22,5 m – 90 connector
27.P/N 43682-K109-08 Cable assy 25,0 m – 90° connector
28.P/N 43682-K261 Loom
29.P/N 43782-K120 Control unit LCD display
30.P/n 43782-K178 Main processor board with LCD
31.P/N 44782-K071-02 Main processor board new version Mk6
32.P/N 44782-K071-02 Main processor board new version Mk6
33.P/N 44782-K098-01 8 engine status display board
34.P/N 44782-K102-02 Status display board
35.P/N 44782-K182 EEPROM
36.P/N 44782-K183X Interface board (replaces 44782-K085)
37.P/N 44782-K184 Junction box board (replaces 44782-K117)
38.P/n 53836-K170 Control Unit (Bulkhead Mount)
39.P/N53836-K206 Control Unit (Flush Mount)
40.P/N53836-K224-03 Junction box 3 inputs, with 2x25mm plastic glands
41.P/N 53836-K224-05 Junction box 5 inputs, with 2x25mm plastic glands
42.P/N 53836-K224-06 Junction box 6 inputs, with 2x25mm plastic glands
43.P/N 53836-K224-07 Junction box 7 inputs, with 2x25mm plastic glands
44.P/N 53836-K224-08 Junction box 8 inputs, with 2x25mm plastic glands
45.P/N 53836-K224-09 Junction box 9 inputs, with 2x25mm plastic glands
46.P/N 53836-K224-10 Junction box 10 inputs, with 2x25mm plastic glands
47.P/N 53836-K224-11 Junction box 11 inputs, with 2x25mm plastic glands
48.P/N 53836-K224-12 Junction box 12 inputs, with 2x25mm plastic glands
49.P/N 53836-K224-14 Junction box 14 inputs, with 2x25mm plastic glands
50.P/N 97450002 Cable black 7 x 0,5mm2
51.P/N C9189-801 Switch window label
52.P/N D4720-001-02 Junction box 2 inputs, with 2x20mm plastic glands
53.P/N D4720-001-07 Junction box 7 inputs, with 2x20mm plastic glands
54.P/N D4720-001-08 Junction box 8 inputs, with 2x20mm plastic glands
55.P/N D4720-001-09 Junction box 9 inputs, with 2x20mm plastic glands
56.P/N D4720-001-10 Junction box 10 inputs, with 2x20mm plastic glands
57.P/N D4720-001-11 Junction box 11 inputs, with 2x20mm plastic glands
58.P/N D4720-001-12 Junction box 12 inputs, with 2x20mm plastic glands
59.P/N D4720-001-14 Junction box 14 inputs, with 2x20mm plastic glands
60.P/N D5622-001 Detector head electronics only
61.P/N D9221-024 Spares kit (straight connector)
62.P/N D9221-025 Spares kit (90° connector)
63.P/N E3561-301 Detector head complete
64.P/N E3561-301-01 Detector (Short sample pipe)
65.P/N MT0021 Download cable
66.P/N P57100-113 EPROM
Replacement EEPROM Available for Replace EEPROM error.
We provide Complete MK6 troubleshooting, fault finding and service on all ports worldwide.
Comms fault error:
Identifying the cause:-
Communications fault may be caused by:
Incorrectly / poorly screened cables.
Detector failure
Incorrectly wired detector
Detector cable failure
Junction Box failure
Control Panel to Junction Box connection failure
Interface Board failure
Main Processor Board failure
Electrical noise on the communication lines
In the event of a loss of communications with all detector it is not possible to
identify the failure without specialized equipment.
The failure may be either the Control Panel Interface Board or the Main
Processor Board.
Replace the Interface Board first.
If this does not eliminate the fault replace the Main Processor Board.